By using a lab-scale ozone contactor, the optimum condition for operation was obtained at
ozone dose of 1.5 mgO3/mgDOC, pH 8.5, and contact time of 15 minutes. Under this condition,
the removal efficiencies of THMFP, DOC, iron (II), total iron, and manganese were 41 %, 29 %,
23 %, 2 %, and 76 %, respectively. The results also confirmed that ozone was more effective
than chlorine as a pre-oxidant in terms of turbidity, color, manganese, DOC, and THMFP
removals but not for iron. Pre-ozonation also reduced the activity of organic compounds for
THMs formation, which decreased from 180 to 150 μgTHMFP/L-mgDOC after pre-ozonation.
Future works may be focus on setting-up a pilot-scale for pre-ozonation placed at Tan Hiep
Water Treatment Plant to improve the water quality under continuous increase of pollution in
Saigon River.
6 trang |
Chia sẻ: honghp95 | Lượt xem: 519 | Lượt tải: 0
Bạn đang xem nội dung tài liệu Application of pre-Ozonation for removal of disinfection by- products pre-cursor from Saigon river water - Bui Thi Thanh Loan, để tải tài liệu về máy bạn click vào nút DOWNLOAD ở trên
Journal of Science and Technology 54 (2A) (2016) 281-286
APPLICATION OF PRE-OZONATION FOR REMOVAL OF
DISINFECTION BY- PRODUCTS PRE-CURSOR FROM SAIGON
RIVER WATER
Bui Thi Thanh Loan
1
, Vo Minh Phuong
1
, Phan Thanh Hiep
1
,
Tran Kim Thach
2
, Vo Minh Chau
2
, Nguyen Minh Tri
1
,
Nguyen Nhat Huy
1
, Tran Tien Khoi
1
and Nguyen Phuoc Dan
1,
*
1
Ho Chi Minh city University of Technology, VNU – HCM, 268 Ly Thuong Kiet Street,
District 10, Ho Chi Minh City
2
Saigon Water Supply Company (SAWACO), No. 1, Cong Truong Quoc Te Street,
Ward 6, District 3, Ho Chi Minh City
*
Email: npdan@hcmut.edu.vn
Received: 1 April 2016; Accepted for publication: 15 June 2016
ABSTRACT
This study aimed to apply pre-ozonation for removal of disinfection by-products precursors
to reduce the formation of trihalomethanes (THMs) in Saigon river water. The pre-ozonation
process was conducted in a lab-scale ozone contactor. The raw water sample was collected from
Saigon River at the Hoa Phu pump station in Cu Chi District, Ho Chi Minh City. The suitable
condition for pre-ozonation was found. At ozone dose of 1.5 mgO3/mgDOC, pH of 8.5, and
contact time of 15 minutes, the removal efficiency of turbidity, color, iron, manganese, dissolved
organic carbon (DOC), trihalomethanes formation potential (THMFP) were 36 %, 25 %, 56 %,
81 %, 35 %, and 46 %, respectively. These results indicated that the pre-ozonation could reduce
DOC concentration and thus resulted in significant mitigation of THMs formation. In
comparison with pre-chlorination, THMFP of raw water pretreated by pre-ozonation was lower.
Moreover, this study showed that the pre-ozonation was more effective than pre-chlorination in
terms of turbidity, color, manganese, and DOC removals.
Keywords: disinfection by-products (DBPs), THMFP, pre-ozonation, pre-chlorination.
1. INTRODUCTION
Disinfection is a significant step in drinking water treatment to eradicate and inactivate
pathogens for public health protection but may cause other issues to human health due to its
disinfection by-products (DBPs) [1]. The major DBPs found in water supply are trihalomethanes
(THMs), haloacetic acids (HAAs), haloacetonitriles, chlorophenols, and chloral hydrate, which
are products formed during the oxidation of natural organic matters (NOMs) in water by
chlorine (Cl2). Analytical and epidemiological studies have shown that DBPs may cause various
Bui Thi Thanh Loan et al.
282
health when using water for drinking and other purposes [2, 3]. Various techniques have been
applied for DBPs control, such as removal of DBPs precursors, using disinfection alternatives,
and DBPs removals. Among these techniques, the removal of DBPs precursors (e.g. removal of
NOMs in water source) appears to be one of the best candidates for DBPs reduction and pre-
ozonation seems to be an effective method for NOMs removal in various water sources [4, 5].
The application of ozonation in water treatment system also have several other advantages, such
as disinfection, removal of taste and odor, oxidation of iron and manganese, enhancement in
coagulation and filtration, and increase in the biodegradability of NOMs [6, 7].
With the industrialization in the South East of Vietnam, water quality of Saigon River, the
main source for water supply of Ho Chi Minh City, has been degraded with increasing
concentration of iron, manganese, nitrogen, pathogen and organic compounds due to the poor
wastewater management in the upstream. In order to maintain the supply water quality, Tan
Hiep Water Treatment Plant (THWTP) used chlorine for pre-oxidation purpose. Our previous
study assessed THMs formation potential at unit operations of THWTP and results showed that
average total THMs after disinfection were 155.8 μg/L [8]. This value was higher than the
allowable value in drinking water quality standards of The European Communities but lower
than that of Vietnam. However, with the increasing of organic and ammonia pollution of Saigon
River, it is necessary to look for alternatives for chlorine use in pre-oxidation process to ensure
both the water quality and the reduction of THMs formation in the future.
In this work, a lab-scale ozone contactor was used as the pre-oxidation step to remove
DBPs precursors in Saigon River water. The optimum operational condition such as pH, reaction
time, and ozone dose was obtained for this water source. Water quality was evaluated based on
the removal efficiency of turbidity, color, iron, manganese, dissolved organic carbon (DOC), and
trihalomethanes formation potential (THMFP). The performances of ozone and chlorine as pre-
oxidants for water treatment and THMFP removal were evaluated for raw water sample.
2. MATERIALS AND METHODS
Raw water used in the experiments was collected directly from Saigon River (Hoa Phu
Pumping Station - THWTP). Water quality parameters including pH, turbidity, color, ferrous
ion, total iron, manganese, alkalinity, total organic carbon (TOC), DOC, THMFP, and O3 in
water/air were analyzed using Standard Methods [9]. Details on water treatment processes at
THWTP, water sampling and analysis, and raw water characteristics can be found in our
previous study [8].
Pre-ozonation tests were conducted using a batch ozone contactor as illustrated in Figure 1.
Ozone source was from an ozonator (70W, Lino, Vietnam). Water was pumped from raw water
tank (1) into the ozone contactor (2) using a water pump (3). The ozone contactor in cylindrical
shape (D × H = 0.04 m × 2 m and volume of 1.5 L) was made from acrylic. Ozone was bubbled
at the bottom of the contactor with flowrate controlled by a flowmeter (maximum flowrate of 1
L/min). pH values were controlled using a pH controller with a pH probe (Hana Instrument)
placed inside the contactor, a chemical pump, and a Ca(OH)2 solution tank.
The pre-ozonation study was divided into two sets of experiments. In the first set, optimum
experiments were conducted by varying operational conditions such as ozone doses of 0.5 - 3.0
mgO3/mgDOC, pH values in range of 6.5 - 9.0, and contact time from 5 to 30 minutes. After
each experiment, water parameters such as excess ozone in water and in air, pH, turbidity, color,
alkalinity, DOC, and BDOC were analyzed. The optimum ozone dose, pH value, and contact
Application of pre-ozonation for removal of disinfection by-products precursor from
283
time were chosen based on the highest DOC removal efficiency. In the second set, the optimum
condition was then applied to investigate the performance of pre-ozonation on raw water sample.
The pre-chlorination test was also conducted the chlorine dose of 3.86 mgCl2/L for 30 minutes
(according to the operational condition at THWTP in 2015). The parameters for evaluation
included turbidity, color, alkalinity, iron, manganese, DOC, and THMFP after pre-ozonation and
pre-chlorination.
Figure 1. Lab-scale pre-oxidation
system using ozone.
Figure 2. Water treatment efficiency at pH 8.5,
contact time of 15 minutes, and different ozone
doses.
3. RESULTS AND DISCUSSION
3.1. Effects of ozone dose, pH, and contact time on pre-ozonation
The effect of ozone dose on water treatment efficiency is presented in Figure 2. Ozone
consumption efficiency increased from 29 % to 87 % when ozone dose increased from 0.5 to 3
mgO3/mgDOC, which may be due to the mixing condition caused by ozone flow at the bottom
of the contact column. The removals of turbidity and color were also increased with the increase
of ozone dose from 0.5 to 1.5 mgO3/mgDOC and slightly increased to reach the highest values at
34 % and 35 %, respectively, when ozone dose reached 1.5 mgO3/mgDOC. The increase of
ozone consumption and the reaction of ozone with humic/fulvic acid and suspended solids could
be the reasons for this [10]. Surface water contains NOMs, which cause color, turbidity, and
THMs formation after disinfection process using chlorine. NOMs were reported to be effectively
removed by ozonation and usually evaluated by using DOC [11, 12]. As seen in Figure 2, DOC
removal was very low with efficiency of 2 % at low ozone dose (0.5 mgO3/mgDOC) while it
reached the highest efficiency of 36 % at ozone dose of 1.5 mgO3/mgDOC. This was consistent
with results reported in the literature about the limit of ozone dose in pre-oxidation processes,
where ozone dose above this value had almost no effect on DOC removal [11, 13].
Figure 3 displays the effect of pH on the performance of ozonation. It was stated that pH
value of water sample is an important parameter because it relates to hydroxide ion (OH*)
concentration in water, which enhances the reaction of ozone [14]. As can be seen in Figure 3,
the ozone consumption increased which the increase of pH value. As results, the removal
efficiencies of turbidity and color were low in pH range of 6.5 – 7.5 but then quickly increased
when pH increased from 7.5 to 8.5. However, these efficiencies decreased when pH further
0
20
40
60
80
100
0 0.5 1 1.5 2 2.5 3 3.5
E
ff
ic
ie
n
c
y
(
%
)
Ozone dose (mgO3/mgDOC)
Ozone
Turbidity
Color
DOC
Bui Thi Thanh Loan et al.
284
increased from 8.5 to 9, which may be due to the comparative consumption of OH* radical by
alkalinity (i.e. HCO3
-
and CO3
2-
) at high pH values. For NOMs removal, pH appeared to have a
little effect on the removal of DOC, which slightly increased from 23 % at pH = 6.5 to 33 % at
pH = 9.0. Results from these experiments demonstrated that pH 8.5 was the optimum condition
for ozonation, whereby the highest removal efficiencies for turbidity, color, and DOC were
achieved.
Figure 3. Water treatment efficiency at ozone
dose of 1.5 mgO3/mgDOC, contact time of 15
minutes, and different pH values.
Figure 4. Water treatment efficiency at ozone
dose of 1.5 mgO3/mgDOC, pH 8.5, and
different contact times.
The effect of contact time on the ozonation is exhibited in Figure 4. Ozone consumption
increased when contact time increased from 5 to 15 minutes, but decreased when contact time
further increased from 15 to 30 minutes. The fixed ozone dose in this experiment was controlled
by the flowrate and the contact time (i.e. the total ozone amount in the inlet was not changed).
Therefore, the mixing condition should be the limiting factor for long contact time (low
flowrate) while mass transfer could be the controlling factor for short contact time (high
flowrate). The removals of turbidity and DOC were in according with the ozone consumption,
both reached highest efficiencies at contact time of 15 minutes.
The removal of color was slightly different from that of DOC (Figure 4). At contact time of
5 minutes, the removal efficiency of DOC was only 2 % while that of color was 14 %. In
contrast, the removal efficiency of DOC was 15 % while that of color was only 3 % at contact
time of 30 minutes. These could be due to the oxidation level of ozone with different contact
times. With long contact time of 15 minutes, reaction conditions (e.g., the highest ozone
consumption, mixing condition, and reaction time) were sufficient for completed oxidation of
NOMs, which gave high DOC removal. Meanwhile, short contact time of 5 minutes could
partially convert humic/fulvic acids to simple compounds instead of completed oxidation, which
resulted in low color but high DOC content. At this contact time, ozonation had high removal of
color and the highest efficiencies for ozone consumption, DOC and turbidity removal; therefore,
it was chosen as optimum condition.
3.2. Water treatment using ozone and chlorine as pre-oxidants
Figure 5 presents the performance of pre-oxidation using ozone and chlorine for raw water
samples. In Figure 5(a), the removal of turbidity and color using ozone was 15 % and 8 %,
respectively. Although the removal efficiencies by chlorination were comparable with those by
ozonation, ozone is preferred because it also acts as a coagulant aid, which enhances the
removal of turbidity and color during coagulation and flocculation processes [15, 16]. Results
also showed that ozone was better than chlorine for manganese removal (i.e., 76 % and 55 %,
,0
,20
,40
,60
,80
,100
,6.0 ,6.5 ,7.0 ,7.5 ,8.0 ,8.5 ,9.0 ,9.5
E
ff
ic
ie
n
c
y
(%
)
pH
Ozone Turbidity Color DOC
,0
,20
,40
,60
,80
0 5 10 15 20 25 30 35
E
ff
ic
ie
n
c
y
(
%
)
Time (min)
Ozone Turbidity Color DOC
Application of pre-ozonation for removal of disinfection by-products precursor from
285
respectively), but not for iron (II) (i.e., 23 % and 41 %, respectively) as well as total iron
removals, which may be due to the inhibition of organic compounds in iron oxidation [7].
Moreover, DOC removals was 29 % after ozonation, which was more effective than chlorination
for DOC removal (16 %).
The formation of THMs can be reduced by removal of NOMs employing ozonation as pre-
oxidation step, which is demonstrated in Figure 5(b). The THMFP of raw water were relatively
high at 983 μg/L. After pre-oxidation, these values decreased to 582 μg/L (ozonation) and 685
μg/L (chlorination), corresponding to removal efficiencies of 41 and 30%, respectively. This
revealed that pre-ozonation was more effective than pre-chlorination for THMFP reduction,
corresponding to DOC removal efficiencies of 29 %, and 18 % (Figure (5a)). The higher
efficiencies of THMFP reduction as compared to those of DOC removal implied that THMFP
reduction depended not only on the removal of DOC but also on the conversion of organic
compounds (e.g. conversion of hydrophobic DOC into hydrophilic DOC instead of DOC
removal [17]), which decreased the activity of the organic compounds for THMs formation.
Among the water samples, only pre-chlorinated sample contained initial THMs of 135
µg/L, which meant that chlorine did not exist in raw water of Saigon River. Therefore, pre-
oxidation with chlorine would finally produce more THMs than that with ozone, and ozone
would be more effective than chlorine in reduction of THMFP. It is also noted that only
chloroform was detected when analyzing THMs, which implied that bromide ion was not found
in raw water. This could be an advantage for employing ozone as a pre-oxidant without
formation of hazardous bromate.
Figure 5. Results of pre-ozonation (1.5 mgO3/mgDOC, pH 8.5, and 15 minutes) and pre-chlorination
(3.86 mgCl2/L): (a) removal efficiency and (b) THMs.
4. CONCLUSIONS
By using a lab-scale ozone contactor, the optimum condition for operation was obtained at
ozone dose of 1.5 mgO3/mgDOC, pH 8.5, and contact time of 15 minutes. Under this condition,
the removal efficiencies of THMFP, DOC, iron (II), total iron, and manganese were 41 %, 29 %,
23 %, 2 %, and 76 %, respectively. The results also confirmed that ozone was more effective
than chlorine as a pre-oxidant in terms of turbidity, color, manganese, DOC, and THMFP
removals but not for iron. Pre-ozonation also reduced the activity of organic compounds for
THMs formation, which decreased from 180 to 150 μgTHMFP/L-mgDOC after pre-ozonation.
Future works may be focus on setting-up a pilot-scale for pre-ozonation placed at Tan Hiep
Water Treatment Plant to improve the water quality under continuous increase of pollution in
Saigon River.
Acknowledgements. The authors gratefully acknowledge the financial support from HCMC Department
of Science and Technology and Saigon Water Supply Company (SAWACO).
0
20
40
60
80
100
Chlorination Ozonation
R
e
m
o
v
a
l
(%
)
Turbidity Color
Mn Fe(II)
Fe (total) DOC
(a)
0
20
40
60
0
200
400
600
800
Chlorination Ozonation
R
e
m
o
v
a
l
(%
)
T
H
M
(
μ
g
/L
)
THMo THMFP Removal(b)
Bui Thi Thanh Loan et al.
286
REFERENCES
1. Agus E., Voutchkov N., Sedlak D. L. - Disinfection by-products and their potential impact
on the quality of water produced by desalination systems: a literature review, Desalination
237 (2009) 214-237.
2. Weinberg H. S., Krasner S. W., Richardson S. D., Thruston Jr A. D. - The occurrence of
disinfection by-products (DBPs) of health concern in drinking water: results of a
nationwide DBP occurrence study, in, National Exposure Research Laboratory, Office of
Research and Development, US Environmental Protection Agency, 2002.
3. Richardson S. D., Postigo C. - Drinking water disinfection by-products, in: Emerging
organic contaminants and human health, Springer, 2011, pp. 93-137.
4. Reckhow D. A., Singer P. C. - The removal of organic halide precursors by preozonation
and alum coagulation, Journal (American Water Works Association), (1984) 151-157.
5. Chiang P. C., Chang E. E., Chuang C. C., Liang C. H., Huang C. P. - Evaluating and
elucidating the formation of nitrogen-contained disinfection by-products during pre-
ozonation and chlorination, Chemosphere 80 (2010) 327-333.
6. Li T., Yan X., Wang D., Wang F. - Impact of preozonation on the performance of
coagulated flocs, Chemosphere 75 (2009) 187-192.
7. Reckhow D. A., Knocke W. R., Kearney M. J., Parks C. A. - Oxidation of iron and
manganese by ozone, Ozone: science & engineering 13 (1991) 675-695.
8. Trang V. N., Phuong L. D., N.P. Dan, B.X. Thanh, C. Visvanathan - Assessment on the
trihalomethanes formation potential of Tan Hiep Water Treatment Plant, J Water Sustain,
2 (2012) 43-53.
9. Clesceri L. S., Eaton A. D., Greenberg A. E., Association A. P. H., A. Association W. W.,
W. E. Federation - Standard Methods for the Examination of Water and Wastewater,
American Public Health Association, 1998.
10. Gilbert E. - Biodegradability of ozonation products as a function of COD and DOC
elimination by the example of humic acids, Water research, 22 (1988) 123-126.
11. Siddiqui M. S., Amy G. L., Murphy B. D. - Ozone enhanced removal of natural organic
matter from drinking water sources, Water Research, 31 (1997) 3098-3106.
12. Chang C. N., Ma Y. S., F. F. Zing, - Reducing the formation of disinfection by-products
by pre-ozonation, Chemosphere 46 (2002) 21-30.
13. Yan M., Wang D., Shi B., Wang M., Y. Yan, - Effect of pre-ozonation on optimized
coagulation of a typical North-China source water, Chemosphere 69 (2007) 1695-1702.
14. Staehelin J., Hoigne J. - Decomposition of ozone in water: rate of initiation by hydroxide
ions and hydrogen peroxide, Environ. Sci. Technol. 16 (1982) 676-681.
15. Reckhow D. A., Edzwald J. K., Tobiason J. E. - Ozone as an Aid to Coagulation and
Filtration, Foundation and American Water Works Association, 1993.
16. Farvardin M. R., Collins A. G. - Preozonation as an aid in the coagulation of humic
substances—optimum preozonation dose, Water Research 23 (1989) 307-316.
17. Galapate R. P., A.U. Baes, M. Okada, - Transformation of dissolved organic matter during
ozonation: effects on trihalomethane formation potential, Water Research, 35 (2001)
2201-2206.