Among more than 280 exposed hot water
sources discovered in Vietnam, the
geothermal sources with the indication of
magmatic origin reflecting from their
geochemical characteristics, geologicaltectonic conditions, and geothermal regime
are concentrated in the Central Region. Since
the geothermal sources of this type were
recognized as aspiring objects for electricity
power generation, therefore, explorations to
develop electrical energy in the coming time
should be better to concentrate in the Central
Region.
The conducted exploration surveys
including geophysical and geochemical
techniques applied in this study effectively
defined the location, structural feature,
thermal state as well as the origin of the
geothermal reservoir in the Bang hot spring
area. The similarity in the parameters of the
reservoir to the Worldwide conceptual model
of a hydro- geothermal system is a good basis
for deployment of a test drilling in the next
phase of the geothermal program.
The successful determination of the
geothermal reservoir in the Bang area
indicates a correct methodology and
techniques chosen for the exploration and data
acquisition. The techniques used and the
practical experiences accumulated in this
study by the participants can serve as effective
tools to assess the other geothermal
perspective objects in different locations in
order to establish the database of geothermal
energy potential and propose the strategy for
geothermal energy exploitation as a renewable
energy resource in Vietnam.
14 trang |
Chia sẻ: honghp95 | Lượt xem: 520 | Lượt tải: 0
Bạn đang xem nội dung tài liệu Identification of geothermal reservoir from exploration data in the Bang hot spring area, Central Vietnam, để tải tài liệu về máy bạn click vào nút DOWNLOAD ở trên
Vietnam Journal of Earth Sciences, 39(3), 289-302, DOI: 10.15625/0866-7187/39/3/10590
289
(VAST)
Vietnam Academy of Science and Technology
Vietnam Journal of Earth Sciences
Identification of geothermal reservoir from exploration data in the
Bang hot spring area, Central Vietnam
Tran Anh Vu, Doan Van Tuyen, Tran Tuan Anh, Dinh Van Toan, Lai Hop Phong*
Institute of Geological Sciences, VAST, Hanoi, Vietnam
Received 05 April 2017. Accepted 02 August 2017
ABSTRACT
Worldwide literature shows that the potential for electricity generation of every geothermal source is depended on
the local condition, so the exploration phase is an important step in the geothermal power development to identify the
site, structural feature and temperature parameters of a geothermal system-reservoir. The paper presents some results
of the first experiment carried out by using a combination of geological, geochemical, geophysical methods, and tem-
perature measurements in shallow drilling hole (depth 250 m) were applied for investigation in the Bang hot water
spring area, Quang Binh province, during the period from 2012 to 2015. The location and structural feature of geo-
thermal reservoir identified by the resistivity model obtained from the magneto-telluric survey and geochemical anal-
ysis was a good consistency with the existent reservoirs of a typical hydro-geothermal system of magmatic origin.
The temperature gradient and heat flow at the shallow drilling hole are reached 4.1°C/100m and 83.4 mW/m2, respec-
tively. The reservoir temperatures estimated by both geochemical thermometer and temperature modeling are varied
in a range 167-200°C at the depth >2 km. The obtained results allow to determine the suitable location for test drill-
ing to the reservoir and to propose for the next phase of the Geothermal Program in the area.
Keywords: Bang hot spring, geochemical thermometer, hydrothermal source, magma, magnetotelluric method,
geothermal reservoir.
©2017 Vietnam Academy of Science and Technology
1. Introduction1
Utilization of geothermal energy, one of
the renewable power types is a great concern
in the world. Until 2014 the capacity of elec-
trical power generated from geothermal
sources was reached 12,635 Mw in 24 coun-
tries (Bertani, 2015). Comparison of charac-
teristic parameters of site distribution, chemi-
cal composition, geological condition, strati-
graphic and geothermal regime, etc. of hot
water sources in Vietnam with several world-
*Corresponding author, Email: laihopphong@yahoo.co.uk
wide representative power generating geo-
thermal sources found was a number of hy-
dro-geothermal systems in the Central Region
matching the criteria needed for exploration.
The geothermal water is characterized by the
peripheral reservoir composition. The geo-
thermal springs are distributed in the regions
covered by Neogene-Quaternary, including
Holocene basaltic formations in Truong Son,
Kon Tum and Lam Dong terrains (Phan Cu
Tien, 1992; Nguyen Hoang et al., 1996, Tran
Van Tri, 2004), characterized by high heat
flow anomaly >80 mW/m2 (Dinh Van Toan et
Tran Anh Vu, et al./Vietnam Journal of Earth Sciences 39 (2017)
290
al., 1996; He Lijuan, 1999; Tran Huyen et al.,
1999).
Since the 1980s, Vietnamese and foreign
researchers, as well as investors (ORMAT),
have reached a conclusion that geothermal
resources in Vietnam are favorable for the
development of energy generation, but
additional surveys are needed (Flynn, 1997).
To solve this problem, in 2012 under the
financial support by the National Program
“Scientific Research and Technology for
disaster prevention, environmental protection
and rational use of natural resources” coded
KC08/11-15, for the first time in Vietnam, the
exploration phase was approved and related
works were conducted during the period from
2012 to 2015 in the Bang hot spring area of
Quang Binh province. The important task of
the exploration was to understand the
distribution, structural and temperature
parameters of the geothermal system. A
combination of geological, geophysical,
geochemical techniques was employed among
the other applied geophysical methods such as
magnetotelluric survey, which played one of
the key roles. The borehole temperature
measurements were also conducted.
The geological map and distribution
scheme of geothermal springs of Vietnam
are presented in Figure 1. The chemical
compositions and temperatures of hot water
samples taken from 287 sites are reported in
the monograph “Geothermal resource in
Vietnam and perspectives of their use for
energy purposes” (Vo Cong Nghiep, 1998).
The estimation of electricity generation
potential of geothermal systems can be
realized by comparing their structural and
geothermal parameters obtained from the
exploration and analytical data in this study
with those parameters characterized for a
Worldwide conceptual model of a hydro-
geothermal system and the geothermal fields
used for electricity generation in different
countries nowadays (Di Pippo, 2012; IGA
report, 2013). In this case, a simple method
such as experimental graphic (GeothermEx,
2004; Chandrakharam, 2008) using the
structural elements, temperature and flow rate
of geothermal fluid of reservoir can be applied
for the estimation.
Figure 1. Manifestation of geothermal resource on the
geological map of Vietnam
Legend: Temperature of water: 1) 30 -40oC; 2) 41-60oC;
3) >61oC; 4) Index of water site
2. Survey data in the Bang hot spring area
The exploration was conducted in the area
of Bang hot water spring and its adjacent,
where the flow rate of the exposed hot water
source measured on the surface is 40l/s with
water temperature reached 100°C (the highest
temperature among the geothermal sources in
Vietnam). The detail geological condition of
the area obtained in this study is presented in
Figure 2. Some parameters such as physical
Vietnam Journal of Earth Sciences, 39(3), 289-302
291
properties, chemical compositions, and hot
water utilities for this site were partly
described in the previous studies (Vo Cong
Nghiep, 1998). This hot water source also is
one of the selected locations of the ORMAT
Group (US) for investment with the
expectation to develop electricity energy
(Flynn, 1997).
2.1. Methodology
The exploration conducted in the area of
Bang and surroundings was involved
geological and tectonic surveys for getting the
information about stratigraphic features,
lithological composition of geological
formations, magmatic activities, distribution
of faults and its recent tectonic activities
(following the guide to resource data
collection, analysis, and presentation for
Geothermal projects and IGA report, 2013).
These elements are closely related to the
condition and mechanism of appearance and
existence of geothermal sources.
To understand the physical nature of the
exposed water source, the geochemical
analysis of dissolved concentration of the
major and trace elements was carried out on
20 water samples collected in the
surroundings of hot water spring including hot
geothermal water, warm water, and cold
water. The analysis for 18O, 2H, 3H isotopes
was applied for 5 samples from the hot spring
and rain water. Chemical analysis of water
samples was conducted at the Chemical
Analysis Center at the Institute of Geological
Sciences (IGS, VAST) and isotopic analysis
was performed at the Nuclear Center of Rome
University (Italy). The information suggestive
the origin, properties of geothermal solution
and temperature of the reservoir are illustrated
on the chart-StanfordGW.xls Liquid Analysis
_v1_Powell-2010 after input of the obtained
chemical data (Powell T. and Cumming M.
2010).
The geophysical investigations were
carried out using electromagnetic and seismic
methods. Since the magnetotelluric (MT)
survey allowed to reveal not only the
distribution, deep structural features, but also
the parameters related to the physical property
of a geothermal system, so the method plays a
key role in the exploration (Munoz, 2014).
The measurements were fulfilled by MT
equipment MTU2000 (made in Canada) in 43
points in the area of 2-4 km in radius from
the Bang hot-water source. The seismic
exploration in this study was mainly applied
to supply additional information on the
structures of the expected reservoir itself. The
data collection was carried out using 150
wireless Texan seismic instruments (USA)
along 4 profiles with their length varied from
8 to 11.5 km in the study area. The results of
MT data interpretation allowed to predict the
existence of a geothermal reservoir and heat
supply source in the study area (Doan Van
Tuyen et al., 2014; 2015). The seismic data
revealed a fracture zone distributed above the
MT defined a geothermal reservoir in the
extension structure restricted by the 2 local
sub-meridian tectonic faults (Tran Anh Vu et
al., 2016). According to the results, the
geophysical parameters obtained from data
interpretation (mainly resistivity parameters)
indicated that the structural elements of the
geothermal system satisfied the worldwide
conceptual model of the hydro-geothermal
system from the international literature (IGA
report, 2013; Munoz, 2014).
The surface geothermal survey was carried
out to estimate the thermal gradient and
surface heat flow, etc. For this purpose, the
temperature log was performed after drilling a
shallow drilling hole of 250 m deep created in
the area of expected geothermal reservoir. Its
location was chosen by using geophysical
data. The geothermal conductivity of rocks
was directly measured for the samples taken
from the borehole and its surroundings. The
temperature log was repeated after about 6
months later with the expectation to restore
the geothermal regime in the borehole.
The underground temperature distribution
in the area surrounding the shallow borehole
was derived by modeling technique using
software TOUTH2 (USA) along the MT
section. The surface heat flow and geothermal
Tran Anh Vu, et al./Vietnam Journal of Earth Sciences 39 (2017)
292
gradient used for modeling were calculated
from both the temperature data collected
along the drilling hole and thermal conductivi-
conductivity of the rocks; the crustal structural
parameters are inferred from the
magnetotelluric data and collected from the
previous studies (Bui Cong Que, Nguyen Kim
Lap, 1992, Doan Van Tuyen et al., 2015; Dinh
Van Toan et al., 2015); Other parameters such
as physical properties of the environment
(density, porosity) are defined from the
handbooks (Truong Thu Huong, 2006;
Dortman, 1984; Robertson Eugene, 1988)
followed the petrologic composition of the
geological formations revealed during the
field survey.
Since the surveys conducted at this stage
are implemented on the ground surface,
the received temperature parameters of
geothermal system/reservoir should only be
accepted as the indications of interest.
2.2. Result and discussion
2.2.1. Geological and tectonic survey
The detail geology-geotectonic surveys
conducted in this study (Figures 1, 2), Bang
hot spring is located in the area of NW-SE
trending Khe Giua - Vinh Linh fault. The
intensive right lateral strike - slip motion of
this regional fault constrained by the
extension stress field of subparallel direction
during Late Pliocene - Quaternary time has
created a favorable condition for upward
movement of magmatic structures from the
mantle to the crust. In consequences, the
submedian extension structures were
popularly developed in the region and a
number of basaltic structures of Neogene -
Quaternary ages appeared in the region (about
8 km northwest from Bang hot spring, Vinh
Linh). Those magmatic bodies cannot reach
the surface are called intrusive structures,
while some of them distributed near the
surface become hidden geothermal sources. In
addition, the interaction between the thermal
fluid from some depth upward along the fault
fractured zone with the near-surface ground
water flow may be the reason of the
appearance of Bang hot water spring on the
surface. The age of the Neogene - Quaternary
basalts estimated in the previous studies is
600,000-700,000 years for the basaltic
eruptions N-Q (Phan Cu Tien, 1991) and
350,000 years for the QIV basalt (Nguyen
Xuan Han et al., 1991). The appearance of
Holocene magmatic extrusion in Gio Linh is
probably related to magmatic reactivity in the
Late Pliocene-Quaternary or basaltic injection
occurred later, such as the ash eruption in Tro
Island on the continental shelf of Binh Thuan
province in 1923 (Nguyen Xuan Han et al.,
1991). The intrusive bodies formed at shallow
depth in those regions may have become
hidden heat sources satisfying exploration
conditions for geothermal electricity
(Brikowski et al., 2001; Di Pippo, 2012; IGA
report, 2013). In this sense, the existence close
to the surface of a hot intrusive magmatic
body in the Bang area is possible that can play
a role as the source to supply the heat for the
geothermal reservoir.
Regarding the lithology, in the Bang spring
area widely spread are the following geological
formations: Cambrian-Early Ordovician, Late
Ordovician - Early Ssilurian ages, in which the
lower part of Long Dai (O3-S1ld1-2) and A
Vuong (Є-O1av) sub-formations are composed
of coarse-grained materials with high porosity
(sandy, conglomerate, tuff,). This is a
favorable condition for circulating and
accumulating geothermal water and initiation
of streaming flow to form reservoir and clay
cap. In the subsurface layer distributed are
sedimentary rocks of Middle and Late Long
Dai sub-formations (O3-S1ld2-3) comprising
claystone and siltstone, characterized by low
thermal conductivity that can play a role of
water proof layer. The total thickness of these
sedimentary formations is about 3 km (Phan
Cu Tien, 1991; Tran Van Tri, 2004).
All the mentioned above elements of
geology-geotectonic environment indicate a
good condition for a perspective geothermal
reservoir in the Bang hot spring area.
Vietnam Journal of Earth Sciences, 39(3), 289-302
293
Figure 2. Geological-tectonic map in surrounded area of Bang hot spring
2.2.2. Geochemical data
The water samples used for chemical
analysis were collected in the area of hot
spring and tectonic fault zone (Figure 3).
The results of chemical and isotope
analysis are shown in Table 1 and in the
Appendix.
As shown in Cl-SO4-HCO3 chart, the chemical compositions of samples collected in
the study area indicate the peripheral
geothermal reservoir origin (Figure 3) (Doan
Van Tuyen et al., 2014). The Na-K-Mg
chart obtained from the study showed
disequilibrium condition of a large proportion
of the water, and the non-stop movement of
geothermal water has been rising from the
place near the heat source to surface.
One way to estimate the reservoir
temperature is the use of series of formulas
called geochemical thermometers (Arnorsson,
1985; Fournier, 1977, 1979; Powell and
Cumming, 2010; Truesdell and Fournier,
1977). In this study the geochemical
thermometers termed as
Christobalite/Chalcedony, Na-K-Ca corrected
Mg, and K/Mg were used. In general the
temperature derived from the thermometers
with more or less use of Mg component is
always lower than the other one. In particular,
some less reliable results indicated the value
lower than the temperature of exposed water
on the ground surface were eliminated from
the results (Doan Van Tuyen et al., 2014 ).
The reservoir temperature obtained by the
thermometer Na-K-Ca varied in a range 167-
221°C, equivalent to the average temperature
value of thermometer Na/K and mixed model
silica-enthalpy (210°C) is more suitable,
probably reflects the temperature of the
geothermal reservoir (Table 1).
Tran Anh Vu, et al./Vietnam Journal of Earth Sciences 39 (2017)
294
Figure 3. Locations of water sample collection in the
area of Bang hot spring
The correlation between δ18O and δ2H of
fluids is presented in Figure 5. The results
obtained from the isotope analysis indicated
mixed geothermal water with magmatic
andesite origin. Both hot spring samples
M5(Kb2), M7(Kb5) are located close to the
local meteoric line together with local
groundwater M1 and rain M6 samples,
suggesting that the thermal water discharging
at the hot springs is mostly fed by shallow
groundwater and rainy sources. This
information confirmed the magmatic origin of
the geothermal water in the study area (Figure
5). Mixing line in Bang hot spring distributing
in higher level δ2H than standard one is
explained (e.g. Giggenbach, 1991) by
evaporation of water from East Vietnam Sea
embedded in the rock from ancient Long Dai
sea. The cycle of rainy water circulation
determined by ratio 3H0/3H is around 38
years.
Figure 4. Chart Cl-SO4-HCO3 for water samples in
Bang hot spring
Table 1. Temperature of hot water samples and geothermal reservoir calculated by geochemical thermometers in area Bang
Index of
water
samples
Coodinates of
site (lat, long)
Temp of
water at
surface, T,
°C
Calculated reservoir temperature, T, °C by geochem thermometer
Cristobalit
e/Chal-
cedony
Quartz Na-K-Ca
Na-K-Ca
Mg corr Na/K (*)
K/Mg
Giggen-
bach, 1986
Mixed
model
Silic-
enthalpy
131B 106.83894
17.067905
100 58/79 109 167 87 137-175 93
210
KB1 106.83955
17.068915
96.29 57/78 107 201 78 202-231 97
KB2 106.80032
17.076487
97.12 59/80 109 197 148 174-208 114
KB3 106.75753
17.09163
93.85 53/74 104 186 133 186-221 110
KB4 106.74872
17.093137
90.07 61/82 112 209 110 175-208 106
KB5 106.71632
17.096931
84.13 59/80 110 187 34 162-196 86
Note: Column with symbol (*) is the range of temperature calculated by the 5 formulas - geochemical thermometer
Na/K: Fournier, 1979; Truesdell, 1976; Tonani, 1980; Arnorsson, 1983; Nieva, 1987
Vietnam Journal of Earth Sciences, 39(3), 289-302
295
Figure 5. Diagram δ2H - δ18O for water samples in Bang hot spring indicates andesite origin
2.2.3. Geophysical data
The data of geophysical surveys
successfully identify the location, structural
features of the geothermal system and
reservoir.
The magnetotelluric (MT) survey was
carried out in a dense network of
measurement points (Figure 4, left). In this
paper, only the results related to the indication
of the geothermal reservoir are presented (Di
Pippo, 2012, Munoz, 2014; IGA report, 2013;
Williams et al., 2008). The low resistivity
structure (ρk <10Ohm.m) revealed at a depth
of Z= 3 km from MT data in southern part of
the area (Figure 6, right) suggested the
location occupied the geothermal reservoir on
the plane.
On the 2D resistivity structural model along
B-B’ and C-C’ lines (Figure 7) the indication
of geothermal reservoir is reflected by a very
low resistivity zone (Doan Van Tuyen et al.,
2014; 2015). Thus, the structural feature of the
geothermal system in the Bang area identified
by the geophysical surveys is satisfied the
worldwide conceptual model of a hydro-
geothermal system of magmatic origin
(Brikowski et al., 2001; Wang and Horne,
1999) by both structural elements as well as its
physical properties (Figure 7), such that, (1) the
clay cap detected at depth about 2-3 km plays a
role in preventing the heat transfer from the
geothermal reservoir to subsurface rock layers;
(2) beneath the cap is located the geothermal
reservoir with bottom boundary reaching the
depth up to 6-7 km. The results reveal that the
exposed Bang hot water spring belongs to the
northern peripheral edge of the reservoir; and
(3) deeper in the crust the low resistivity
structure revealed from depth about 10-12 km
can be interpreted as an intrusive body (hot
magma?), which plays a role of the heat supply
source for the geothermal reservoir.
Tran Anh Vu, et al./Vietnam Journal of Earth Sciences 39 (2017)
296
Figure 6. Left: Distribution of MT observation in area Bang hot spring (Legend: 1 - location of hot spring; 2 - point
of MT measurement; 3 - MT cross-section); Right: resistivity countour at depth Z = -3 km indicates geothermal
reservoir in Bang area (Legend: Ba10 - Index site of MT observation; B-B’, C-C’: Line of MT resistivity cross-
section; LK1- site of drill hole)
2.2.4. Subsurface geothermal data
The results of in-situ temperature
measurements conducted along depths of the
borehole LK1 (see Figure 6, right) just after
the end of drilling (24 November 2014) and
repeated about 6 months later (9 May 2015)
is illustrated in Figure 8. The average of the
geothermal conductivity of the drilling core
samples measured in the laboratory is about
2.1 W/m.K The temperature gradient and
heat flow calculated using the repeated log
data reached the abnormal values of about
4.1°C/100 m and 83.6 mW/m2, respectively.
The reservoir temperature was also estimated
by applying 1D temperature modeling
techniques (Gupta, 2007; Lucak C.V., 1988;
Carol A. Stein, 1995). The B-B’ profile
going through the borehole site LK1 was
chosen for calculation. The crustal structural
parameters used for modeling are derived
from magnetotelluric data (Doan Van Tuyen
et al., 2015a, 2015b) under consideration of
regional structures obtained in the previous
studies (Bui Cong Que, Nguyen Kim Lap,
1992; Dinh Van Toan et al., 2015), the
geothermal properties (surface heat flow,
thermal conductivity of rocks) from the
measurements of samples taken from the
shallow drilling hole LK1, and properties of
deeper geological horizontals were selected
from handbooks (Truong Thu Huong (Ed.),
2006; Dortman,1984; Robertson Eugene,
1988). The temperature structural model
obtained from the calculation indicates the
temperature reaching 2000°C in the upper
Vietnam Journal of Earth Sciences, 39(3), 289-302
297
section of the expected geothermal reservoir
at depth about 3 km (Figure 9), that appears
similar to the value of reservoir temperature
determined by most geochemical
thermometers in this study. Based on these
results, the site LK1 can be selected for test
drilling in the next phase to evaluate the
possibility of geothermal energy exploitation.
Figure 7. MT Resistivity cross-section along lines B-B’ (a) and C-C’ (b) reflecting structure of geothermal reservoir.
Legend: Ba10- Site and number of MT survey
Tran Anh Vu, et al./Vietnam Journal of Earth Sciences 39 (2017)
298
Figure 8. Temperature log at site of drilling hole LK1
Figure 9. Temperature model of geothermal reservoir
in area Bang hot spring
Legend: Ba10- Site and number of MT survey; LK- site
of drilling hole
2.2.5. Estimation of electric power of the
geothermal reservoir in the Bang spring area
Based on the structures and temperature of
the reservoir (>167-200°C ), the flow rate of
geothermal fluid of 40l/s defined from field
observation, the electric power to be
generated by the reservoir was estimated. A
simple experimental graphical technique using
the correlation between reservoir temperatures
and the flow rate of water from the source
(Chandrasekharam, 2008) was used. The
exploitation capacity estimated in a range of
3-4 MWe (Figure 10) is derived from the
results characterizing for worldwide statistical
data: stable electricity generation of one
geothermal source in the fault-based non-
active volcanic region not exceeding 10 MWe
(Williams, et al., 2008).
Figure 10. Estimation of Electric power capacity of geothermal reservoir in area Bang hot spring
The estimated capacity of electricity
generation and the similarity of the parameters
of the expected geothermal reservoir in the
Bang area such as reservoir water origin,
structural elements, temperature to the
parameters of the Worldwide conceptual
model of a hydro-geothermal system is the
reliable basis to suggest the test drilling to the
depth of 2.5 km in the next plan. The data
generated in the test-drilling step will be
Vietnam Journal of Earth Sciences, 39(3), 289-302
299
reflected the actual state of the geothermal
reservoir, that can be used to propose the
future plan for construction of a pilot
geothermal power plant.
3. Conclusions
Among more than 280 exposed hot water
sources discovered in Vietnam, the
geothermal sources with the indication of
magmatic origin reflecting from their
geochemical characteristics, geological-
tectonic conditions, and geothermal regime
are concentrated in the Central Region. Since
the geothermal sources of this type were
recognized as aspiring objects for electricity
power generation, therefore, explorations to
develop electrical energy in the coming time
should be better to concentrate in the Central
Region.
The conducted exploration surveys
including geophysical and geochemical
techniques applied in this study effectively
defined the location, structural feature,
thermal state as well as the origin of the
geothermal reservoir in the Bang hot spring
area. The similarity in the parameters of the
reservoir to the Worldwide conceptual model
of a hydro- geothermal system is a good basis
for deployment of a test drilling in the next
phase of the geothermal program.
The successful determination of the
geothermal reservoir in the Bang area
indicates a correct methodology and
techniques chosen for the exploration and data
acquisition. The techniques used and the
practical experiences accumulated in this
study by the participants can serve as effective
tools to assess the other geothermal
perspective objects in different locations in
order to establish the database of geothermal
energy potential and propose the strategy for
geothermal energy exploitation as a renewable
energy resource in Vietnam.
Acknowledgments
This work was supported by the Vietnam
National Program “Scientific Research
and Technology for disaster prevention,
environmental protection and rational use of
natural resources” to project coded
KC08.16/11-15. The first author would like to
thank the leaders of this Project for providing
material to his doctoral research.
References
Arnorsson S., 1985. The use of mixing models and
chemical geothermometers for estimating
underground temperatures in geothermal systems.
J. Volcan. Geoth. Res., 23, 209-335.
Bertani R., 2015. Geothermal Power Generation in the
World 2010-2014 Update Report. Proceedings
World Geothermal Congress 2015 Melbourne,
Australia, 19-25, April 2015, 19p.
Brikowski T., Norton D., Blackwell D., 2001. Final
Report: Natural State Models of The Geysers
Geothermal System, DOE Contract DE-FG07-
98ID13677. December 31.
Bui Cong Que, Nguyen Kim Lap, 1992. Structure of the
Earth’s crust and seismicity in the territory of
Vietnam. The Book published by Vietnam Academy
of Science, 148p.
Carol A. Stein, 1995. Heat flow of the Earth, in the
Book “Global Earth Physics” edited by AGU1995,
144-158.
Chandrasekharam D., Jochen Bundschuh, 2008. Low-
Enthalpy geothermal resources for power
generation. Taylor & Francis Group, London, UK,
172p.
Di Pippo R., 2012. Geothermal Power plant. Principles,
applications, case studies. 3rd edition. Elsevier, 579p.
Dinh Van Toan, Nguyen Trong Yem, Trinh Viet Bac,
1996. The preliminary results of heat flow study in
South Vietnam. Vietnam Journal of Earth Sciences,
18, 74-79.
Dinh Van Toan, Lai Hop Phong, Tran Anh Vu, Nguyen
Thi Hong Quang, 2015. Study on the Earth’s crustal
structure in the area of Song Tranh and it’s
adjacents. Vietnam Journal of Earth Sciences, 37,
127-138 (in Vietnamese). DOI: 10.15625/0866-
7187/37/2/7368.
Doan Van Tuyen, Tran Anh Vu, Nguyen Thi Kim
Thuong, 2014. Geochemical characteristics of
geothermal water sources on the territory of
Vietnam. Proceedings, Thirty-Eighth Workshop on
Geothermal Reservoir Engineering - Stanford
Tran Anh Vu, et al./Vietnam Journal of Earth Sciences 39 (2017)
300
University, California, February 24-26, 2014; SGP-
TR-202, 8p.
Doan Van Tuyen, Tran Anh Vu, Lai Hop Phong, Pham
Ngoc Dat, Le Van Si, Dinh Van Toan, Nguyen Thi
Hong Quang, 2015. Results of magnetotelluric
survey for studying geothermal system in the Bang
area, Quang Binh Province. Vietnam Journal of
Earth Sciences, 37(2), 48-56 (in Vietnamese).
DOI: 10.15625/0866-7187/37/1/6553.
Doan Van Tuyen, Tran Anh Vu, Lai Hop Phong, Pham
Ngoc Dat, Dinh Van Toan, Le Van Si, 2015.
Structural feactures of geothermal Field from
Magnetotelluric Survey in Nothern Cenral region of
Vietnam. Proceedings World geothermal Congress
2015, Melbourne, Australia, 19-25 April 2015, 6p.
Flynn T., Quy H.H., 1997. Assessment of the
geothermal resources of Socialist Republic of
Vietnam. Geothermal resources Council
Transactions, 21, 341-345.
Fournier R.O., 1977. Chemical geothermometers and
mixing models for geo-thermal systems.
Geothermics, 5, 41-50.
Fournier R.O. and Potter R.W. II, 1979. Magnesium
correction to the Na-K-Ca chemical
geothermometer. Geochim. Cosmochim. Acta, 43,
1543-1550.
Fournier R.O., 1979. A revised equation for the Na-K
geothermometer. Geo-thermal Resource Council
Transections, 3, 221-224.
GeothermEx, 2004. New geothermal site identification
and qualification. Consultant report for California
Energy Commission, Richmond, CA.
Giggenbach W.F., 1991. Isotopic composition of
geothermal water and steam discharges. In
D’Amore, F. (editor), Application of Geochemistry
in Geothermal Reservoir Development.
UNITAR/UNDP publication, Rome, 253-273.
Gupta H., 2007. Geothermal Energy: An Alternative
resource for the 21st Century. Elsevier PH. ISBN-13:
978-0-444-52875-9. 285p.
He Lijuan, 1999. Analysis of heat flow along a transect
across the South China Sea. Geothermal Training
Pro-gramme, Reports, 5, 125-140.
IGA report, 2013. Geothermal Exploration best
practices: A Guide to resource data collection,
analysis, and presentation for Geothermal projects.
Lucak C.V., 1988. Heat flow in the Continental rift
zones. Publish House “Nauka” Soviet Union
Academy of Science, Novosibirsk Branch, 198p (in
Russian language).
Munoz G., 2014. Exploring for Geothermal Resources
with Electromagnetic Methods, Surv Geophys, 35,
101-122.
Nguyen Hoang, Flower M., Pham Tich Xuan, 1996. The
petrology of Late Kainozoic Basalts in Vietnam. In
monography “Geology and Natural resource”, P.H.
Science and Technology, Ha Noi, 142-155 (in
Vietnamese).
Nguyen Xuan Han et al., 1991. Young volcano activity
in Vietnam East Sea. In monography “Geology and
Natural resource”, PH Science and Technology, Ha
Noi, 84-96 (in Vietnamese).
Phan Cu Tien et al., 1991. Geology of Cambodia, Laos
and Vietnam. Geological survey of Vietnam, 2nd
edition. Hanoi, 158p.
Powell T. and Cumming M., 2010. Spreadsheets for
Geothermal Water and gas geochemistry.
Proceedings, Thirty-Fifth Workshop on Geothermal
Reservoir Engineering, Stanford University, Stanford,
California, February 1-3, SGP-TR-188, 10p.
Tran Anh Vu, Dinh Van Toan, Doan Van Tuyen, Lai
Hop Phong, Duong Thi Ninh, Nguyen Thi Hong
Quang, Pham Ngoc Dat, 2016. Utilization of seismic
refraction data for study of structure of Bang Hot-
water source, Le Thuy, Quang Binh. Vietnam
Journal of Earth Sciences, 38(4), 393-408.
DOI: 10.15625/0866-7187/38/4/8994.
Tran Huyen, Truong Minh, Nguyen Tien Bao, 1999. On
the geothermal regime in the sedimentary basins,
continental shelf of Vietnam. Journal of economic
geology and mineral materials, Publication of of the
Department of geology and minerals 18, 16-25 (in
Vietnamese).
Tran Van Tri (Project manager), et al., 2004. Map of
geology and mineral resources of Vietnam on scale
1:1,000,000. Publication of the Department of
Geology and mineral recources of Vietnam, Hanoi
(in Vietnamese).
Truesdell A.H. and Fournier R.O., 1977. Procedure for
estimating the tempera-ture of a hot water
component in a mixed water using a plot of
dissolved silica vs enthalpy. US Geol. Survey J.
Res., 5, 49-52.
Vietnam Journal of Earth Sciences, 39(3), 289-302
301
Truong Thu Huong (Ed.), Vo Bich ngoc, Nguyen Duc
Thang, Pham Toan, Nguyen Huu Tri, 2006. Online
Handbook: “Physical properties of Rocks and
Minerals in Vietnam. Publication of Northern
Vietnam Geological Maping Division, Ha Noi, 546p
(in Vietnamese).
Vo Cong Nghiep (Ed.), 1998. Geothermal resource in
Vietnam and perspectives of their use for energy
purposes. Monography Published by Vietnam
Department for Geological and mineral resource.
Hanoi, 300p (in Vietnamese).
Wang C.T., and Horne R.N., 1999. Boiling Flow in a
Horizontal Fracture, Geothermics, 29, 759-772.
Williams C.F., Reed M.J. and Mariner R.H., 2008. A
review of methods applied by the U.S. Geological
Survey in the assessment of identified geothermal
resources, U.S. Geol. Survey Open-File Report
2008-1296, 27p. [ usgs.gov/ of/2008/
1296/].
APPEDIX
Table 1. Chemical components in the area of hot spring Bang
Table 1 (continue table 1). Chemical components in area of hot spring Bang
Table 2. Content of stable 18O - 2H, 3H of water samples in the area of hot spring Bang
NN Index of samples Latitude Longtitude
Temperature
(oC)
18O
(‰SMOW)
2H
(‰SMOW)
3H
(T.U) Note
1 M1 174'10.85 10645'9.00 27.1 - 6.2 - 39.3 10.0 Drill hole LK1 (250 m)
2 M2 174'47.70 10645'13.37 30.5 - 6.4 - 42.1 11.1 Drill hole LK (40 m)
3 M4 174'46.93 10645'16.14 78.1 - 7.3 - 51.4 10.2 Exposed hot water (Kb13)
4 M5 174'49.78 10645'17.45 97.12 - 1.6 - 22.2 0.5 Exposed hot water (Kb2)
5 M7 174'53.72 10645'17.82 84.13 - 1.3 -21.4 nd Exposed hot water (Kb5)
6 M6 174'49.78 10645'17.45 25.0 - 5.7 - 34.2 4.3 Rainy water
NN
Parameters
Unit
Index of samples/ value or content
KB1 KB2 KB3 KB4 KB5 KB6 KB7 KB8 KB9 KB10 KB11 KB12 KB13 KB14 KB15 KB16
1 Temperature oC 96.29 97.12 93.85 90.07 84.13 27.10 28.90 30.3 30.8 29.7 32.4 68.43 78.1 62.0 30.2 34.5
2 Soluble sludge mg/l 378 450 437 448 442 93.4 54 56 39 58 47 243.5 413.5 437.0 51 51
3 pH 8.47 8.51 8.37 8.03 8.45 5.67 6.84 6.51 6.06 6.5 6.71 6.63 8.43 8.28 7.84 6.89
4 Total stiffness mg/l 0.18 0.10 0.16 0.12 0.32 0.66 0.40 0.40 0.30 0.48 0.26 0.60 0.28 0.16 0.50 0.50
5 EC mS/m 58 59.7 58.4 55.5 48.60 11.6 3.7 3.7 3.5 3.9 6.4 25.4 48.6 57 6.0 3.80
6 HCO3- mg/l 294.9 421.2 419.44 419.2 420.1 42.8 30.0 30.0 21.96 34.16 26.60 185.2 385.28 407.0 31.72 31.72
7 CO2 free mg/l 0 0 0 0 0 35.95 8.36 8.36 9.18 9.18 8.36 8.36 0 0 0.42 5.42
8 Ca2+ mg/l 1.20 1.20 2.40 0.40 1.60 6.00 2.00 2.00 1.80 1.60 2.80 6.00 2.00 1.20 3.60 3.20
9 Mg2+ mg/l 1.46 0.50 0.73 0.89 2.92 4.37 3.65 3.65 2.67 4.86 4.86 3.65 2.19 1.21 3.89 4.13
10 Cl- mg/l 29.80 5.10 3.52 4.52 3.71 17.04 7.95 9.37 6.53 9.09 11.36 13.45 4.95 7.10 7.95 9.94
11 K+ mg/l 12.77 13.33 14.40 13.42 11.57 1.33 0.62 1.41 0.71 1.62 2.67 6.38 12.03 13.22 1.05 1.17
12 Na+ mg/l 119.5 152.0 146.7 151.8 149.45 15.06 7.25 6.10 4.84 6.83 7.76 66.85 133.05 147.6 6.05 6.11
13 NO2- mg/l 0.001 <0.001 0.001 <0.001 0.001 0.038 0.015 0.027 0.013 0.025 0.153 0.016 <0.001 <0.001 <0.001 <0.001
14 NO3- mg/l 0.005 <0.001 <0.001 0.001 <0.001 0.95 0.15 0.76 0.083 0.69 1.89 0.426 0.001 <0.001 <0.001 0.394
NN
Parameters
Unit
Index of samples/ value or content
KB1 KB2 KB3 KB4 KB5 KB6 KB7 KB8 KB9 KB10 KB11 KB12 KB13 KB14 KB15 KB16
Temperature oC 96.29 97.12 93.85 90.07 84.13 27.10 28.90 30.3 30.8 29.7 32.4 68.43 78.1 62.0 30.2 34.5
15 NH4+ mg/l 1.27 0.40 0.42 0.40 0.42 0.24 0.20 0.22 0.07 0.22 0.72 0.34 0.53 0.40 0.05 0.01516 H2S mg/l 0.60 0.29 0.29 0.15 0.29 <0.1 0.01 <0.1 <0.1 <0.1 <0.1 2.4 0.86 0.86 <0.1 <0.117 Total S2- mg/l 6.0 4.0 4.0 2.0 4.0 <0.1 0.015 <0.1 <0.1 <0.1 <0.1 4.0 12.0 12.0 <0.1 <0.1
18 SO42- mg/l 8.86 7.49 10.26 7.81 5.40 14.67 4.21 5.84 2.58 4.91 5.37 12.25 7.35 7.47 3.51 3.5119 PO43- mg/l 0.001 0.001 1.25 0.001 0.012 0.015 0.015 <0.001 <0.001 0.013 0.005 2.51 <0.001 <0.001 0.015 <0.00120 Total Fe mg/l <0.001 0.001 <0.001 <0.001 <0.001 0.756 0.352 0.51 <0.001 0.561 1.25 1.73 1.05 0.01 0.125 0.15
21 SiO2 mg/l 55.85 58.23 51.93 61.21 58.91 15.37 16.05 12.65 9.93 12.65 9.59 41.22 59.25 58.57 9.25 7.5522 Mn mg/l 0.007 0.003 0.001 0.005 0.041 0.182 0.009 0.005 0.007 0.003 0.005 0.041 0.001 0.025 0.017 0.013
23 Zn mg/l 0.002 0.021 0.003 0.002 0.002 0.074 0.007 0.023 0.025 0.02 0.012 0.082 0.096 0.055 0.031 0.008
24 Pb g/l 0.03 3.06 1.82 2.15 0.04 3.11 2.43 2.08 2.26 2.25 2.23 2.46 1.63 1.80 2.03 1.88
25 As g/l 1.25 3.86 2.50 1.35 5.02 4.89 2.15 1.05 1.00 2.15 1.37 1.65 1.25 2.05 1.81 3.05
26 Cd g/l 0.137 0.189 0.134 0.137 0.135 0.212 0.152 0.356 0.151 0.141 0.215 0.18 0.171 0.179 0.143 0.134
Tran Anh Vu, et al./Vietnam Journal of Earth Sciences 39 (2017)
302
Table 3. Dating of water by isotope 3H in area of hot spring Bang
NN Index of samples Latitude Longtitude
Temperature
(oC)
3Ho (T.U)
Rainy water
3H (T.U) t (1963) ± year Note
1 M1 174'10.85 10645'9.00 27.1 4.3 10.0 14.93 Drill hole LK1 (250 m)
2 M2 174'47.70 10645'13.37 30.5 4.3 11.1 16.77 Drill hole LK (40 m)
3 M4 174'46.93 10645'16.14 78.1 4.3 10.2 15.28 Exposed hot water (Kb13)
4 M5 174'49.78 10645'17.45 97.12 4.3 0.5 -38.07 Exposed hot water (Kb2)
5 M7 174'53.72 10645'17.82 84.13 4.3 nd nd Exposed hot water (Kb5)
6 M6 174'49.78 10645'17.45 25.0 4.3 4.3 0 Rainy water
Note: nd
Các file đính kèm theo tài liệu này: